Filter by capacity and schedule
Use the filters to narrow the product families to the ones that match your target capacity and timeline. Bands are indicative for orientation only; actual capacity and schedule are confirmed in project assessment.
7 of 7 product families match.
| Product family | Capacity band | Schedule | Typical fit | Scope | Details |
|---|---|---|---|---|---|
| Edge AI skid (single unit) | Under 1 MW | Shortest lead time of the range | Inference nodes, pilot clusters, sites with limited space or power | One AI-IT skid with matched cooling and power skid | View |
| AI-IT compute module | Per-module increments, typically under 5 MW | Factory build plus site interconnection | Adding compute capacity to an existing cooling and power base | Racks, busway, containment, terminal cooling distribution | View |
| Cooling skid / module | Sized to the served compute blocks | Aligned with the compute module schedule | Liquid-cooling retrofit or new high-density cooling base | Primary and secondary loops, CDU, pumps, controls | View |
| MV-HV power skid / module | Scaled per power block | Driven by utility interconnection and equipment lead times | New power base, capacity upgrade, higher redundancy targets | Transformation, switchgear, UPS or DC distribution, metering | View |
| B+IS integrated skid solution | 5-20 MW blocks, repeatable per phase | Prefabrication runs in parallel with site works | Greenfield builds where the whole block is delivered as one product | Compute, cooling, power and storage skids as one integrated block | View |
| PMDC-AI prefabricated data centre | 20 MW and above, campus scale | Phased delivery, each phase repeats the same block | AI computing parks and multi-phase campus programmes | Full prefabricated data centre integration and delivery management | View |
| Energy-storage skid | Added alongside any capacity band | Follows the power skid schedule | Green power integration, peak shaving, ride-through | Battery storage with conversion, thermal management, EMS | View |
AI-IT Compute Skid
High-density GPU rack rows with liquid-cooling manifolds, busway distribution, structured cabling and containment, integrated and pre-tested as one unit.
- Rack density
- 30-80 kW per rack, higher densities on assessment
- Cooling interface
- Cold-plate liquid cooling with rear-door or free-air assist
- Delivery form
- Prefabricated aisle skid or fully enclosed module

Liquid-Cooling & Free-Air Cooling Skid
Primary and secondary cooling loops, CDUs, pumps, filtration and controls on one skid, engineered for Canadian cold-climate free-cooling hours.
- Cooling mode
- Cold-plate liquid loop plus free-air / adiabatic assist
- Target efficiency
- Design target PUE ≤ 1.12, site dependent
- Redundancy
- N+1 pumping and dual-path loops, configurable

MV-HV Power Distribution Skid
Medium and high voltage transformation, switchgear, UPS or DC distribution and metering assembled and factory-tested as a single power block.
- Scope
- MV/HV transformation, switchgear, protection and metering
- Backup
- Modular UPS, battery or generator interface
- Compliance
- North American electrical safety standards

Energy-Storage Skid
Battery storage with integrated conversion, thermal management and EMS controls, supporting green power integration and peak management.
- Role
- Green power integration, peak shaving, ride-through
- Integration
- Solar / hydro interface with EMS coordination
- Scaling
- Added per phase alongside compute capacity

Need the full product manuals?
Datasheets for each skid family are available on request, together with the module-level technical detail pages.