Photo of the liquid cooling distribution unit and piping inside a module
ENGINEERING

Moving the engineering complexity of high-density compute
upstream to the factory

Liquid cooling, power, monitoring, and IT systems are designed and validated within a single engineering framework, leaving only standardized interfaces to connect on site.

LIQUID COOLING

Liquid Cooling Chain

Cold plates remove GPU heat directly; the secondary loop exchanges heat via the CDU into the primary loop, reducing air-side heat exchange losses.

Liquid cooling schematic: cold plates, secondary loop, CDU heat exchanger, and dry cooler
Liquid cooling schematic: GPU cold plate → secondary supply/return → CDU (pump, filtration, plate heat exchanger) → primary loop → outdoor dry cooler.

Direct-to-Chip

Heat is carried away by liquid at the chip level, reducing reliance on room airflow design.

Loop Isolation

The secondary and primary loops are isolated via a heat exchanger, easing zoned maintenance and water quality management.

Factory Validated

Pump sets, filtration, and pressure monitoring are commissioned during factory testing.

Actual thermal configuration and efficiency depend on site climate, water availability, and rack power density; final results are subject to project assessment.

POWER CHAIN

Power Delivery Overview

The power chain from utility intake to rack PDU is prebuilt into the module, with on-site connection and protection configured to site conditions.

Single-line power diagram: utility, transformer, switchgear, UPS, ATS, busway, and rack PDU
Power delivery diagram: utility/transformer → switchgear → UPS & batteries → static transfer switch → busway → rack PDU, with a generator via ATS as backup.
Photo of GPU racks with power distribution and cabling inside a module
On-site photo: power distribution and structured cabling in the rack aisle, powered on and load-tested before shipment.
WHY XAGENT

Not a scaled-down data center
but an entirely new delivery paradigm

Shift on-site engineering to a controlled factory environment, deploy through standardized interfaces, then use software to unify distributed units into a single cluster.

Factory Prefabrication

Core mechanical, electrical, liquid cooling, and IT systems are assembled and tested in a controlled environment.

Native Liquid Cooling

Designed for high-density GPU workloads, reducing retrofit needs and multi-vendor integration risk.

Scale on Demand

Add standard units as your business grows, lowering upfront capital pressure.

Relocatable & Reusable

Modular assets can migrate with compute demand and be redeployed at different sites.

Unified Operations

Manage everything from hardware health to workloads and usage on a single platform.

Reduced On-Site Impact

Shorter on-site construction time and less waste and disruption than traditional builds.